Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 24, 2018, 07:23 AM
  • 18 0085_18 0084 _31072018_160234.mpg

Date
07/24/2018
W/O
716712
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00698
PipeID
P13904
Time
12:23 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5321
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_716712_TV18177_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0085
Downstream MH
18 0084
Dir. of Survey
Downstream
Length Surveyed
281.1 ft.
Total Length
281.1 ft.
Structural Index
3
Structural Quick
3J22
Structural Rating
169
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
169
Pipe schematic from manhole 18 0085 to 18 0084
MH: 18 0085MH: 18 0084downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00856 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start96.2 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES108.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"168.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES181.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"279.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish281.1 ft. AMH - Downstream Manhole, Survey Ends - 18 0084

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    96.2 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    168.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
281.1AMH18 0084
181.7TFC
6SAP
96.2CL
0MWM
279.8SAP
0MWL
168.7CL
108.4TFC
0AMH18 0085

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2018-07-24T00:23:23-07:00
documentation
PROPIPE
is_lateral_inspection
false