Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 29, 2017, 11:17 AM
Date
11/29/2017
W/O
673962
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00042
PipeID
P10265
Time
3:17 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5232
Sewer Name
F JOINT OUTFALL F - UNIT 6
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
34
Purpose
Routine Assessment
Project
WO_673962_TV02160_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
F 0132
Downstream MH
F 0133
Dir. of Survey
Upstream
Length Surveyed
82.2 ft.
Total Length
82.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2B00
O&M Rating
32
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole F 0132 to F 0133
MH: F 0132MH: F 0133upstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 12 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - F 01331.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish80.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start82.2 ft. MWM - Water Mark, 25 %of cross sectional area82.2 ft. MWL - Water Level, 15 %of cross sectional area82.2 ft. AMH - Downstream Manhole, Survey Begins - F 0132

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWM
0MWL
2DAGS
0AMHF 0132
80.6DAGS
82.2MGOACTIVE CONNECTION AT MH 12 O'CLOCK
82.2AMHF 0133

Properties (6)

additional_info
SC346403
custom_field_two
4
customer
LACSD
datetime
2017-11-29T03:17:05-08:00
documentation
PRO PIPE
is_lateral_inspection
false