18 1087_18 1085 _06132019_230544.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start
9.5 ft. - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES
21.9 ft. - Fracture Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES
40.3 ft. - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES
286.8 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES
287.6 ft. - Intruding Sealing Ring Hanging, 5 %of cross sectional area, from 10 to 12 o'clock
325 ft. - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES
342.6 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES
354.6 ft. - Fracture Multiple, from 02 to 09 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 402.6 | DAE | — |
| 40 | LL | — |
| 0 | MWL | — |
| 0 | MWM | — |
| 21.9 | FM | — |
| 354.6 | FM | — |
| 325 | FS | — |
| 40.3 | CM | — |
| 342.6 | FM | — |
| 2 | DAGS | — |
| 2 | DAE | — |
| 404.9 | AMH | 18 1087 |
| 9.5 | FM | — |
| 70 | LL | — |
| 402.6 | DAGS | — |
| 0 | AMH | 18 1085 |
| 287.6 | ISSRH | — |
| 286.8 | CS | — |