Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2019, 11:11 AM
  • E 0198_E 0197_02262019_043852.mp4

Date
02/26/2019
W/O
751206
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00972
PipeID
P24779
Time
3:11 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6455
Sewer Name
E JOINT OUTFALL E - UNIT 4 RELIEF
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_751206_TV01092_FEB2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
E 0198
Downstream MH
E 0197
Dir. of Survey
Downstream
Length Surveyed
321.3 ft.
Total Length
321.3 ft.
Structural Index
3
Structural Quick
4121
Structural Rating
6
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole E 0198 to E 0197
MH: E 0198MH: E 0197downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 01980 ft. MWM - Water Mark, 60 %of cross sectional area68.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES290.1 ft. CS - Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES321.3 ft. AMH - Downstream Manhole, Survey Ends - E 0197

Observation photos (1)

  • Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

    290.1 ft. - Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
321.3AMHE 0197
0MWL
290.1CS
0AMHE 0198
68.8FM
0MWM

Properties (6)

custom_field_two
4
customer
LACSD
datetime
2019-02-26T03:11:50-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
37770