Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2019, 06:05 AM
  • 02 1408_02 1407 _06252019_234533.mp4

Date
06/25/2019
W/O
766518
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00349
PipeID
P02979
Time
11:05 PM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5586
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
WO_766518_TV02365_MAY2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
02 1408
Downstream MH
02 1407
Dir. of Survey
Downstream
Length Surveyed
929 ft.
Total Length
929 ft.
Structural Index
3
Structural Quick
3d00
Structural Rating
555
O&M Index
2
O&M Quick
2d11
O&M Rating
371
Overall Index
3
Overall Quick
Overall Rating
926
Pipe schematic from manhole 02 1408 to 02 1407
MH: 02 1408MH: 02 1407downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 14082 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE2 ft. VC - Vermin Cockroach2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start926 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish926 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish929 ft. MGO - General Observation - CONNECTION IN MH AT 9 AND 3 OCLOCK ACTIVE929 ft. AMH - Downstream Manhole, Survey Ends - 02 1407

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT THROUGHOUT PIPE

    2 ft. - General Observation - MAG COAT THROUGHOUT PIPE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
926SAV
0MWM
2SAV
0MWL
926DAGS
929MGOCONNECTION IN MH AT 9 AND 3 OCLOCK ACTIVE
2MGOMAG COAT THROUGHOUT PIPE
929AMH02 1407
0AMH02 1408
2VC
2DAGS

Properties (6)

additional_info
SC377547
custom_field_two
3
customer
LACSD
datetime
2019-06-25T23:05:22-07:00
documentation
PRO PIPE
is_lateral_inspection
false