Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 31, 2019, 07:40 AM
  • Section#2_B 1270_B 1269__7312019__I0198R.mp4

Date
07/31/2019
W/O
0779342
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01126
PipeID
P25165
Time
12:40 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0198R
Sewer Name
B JOINT OUTFALL B - UNIT 6J
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Maintenance Related
Project
20190731MDM_JOINT_OUTFALL_B_UNIT_6J
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
B 1270
Downstream MH
B 1269
Dir. of Survey
Downstream
Length Surveyed
362.3 ft.
Total Length
362.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4131
O&M Rating
9
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole B 1270 to B 1269
MH: B 1270MH: B 1269downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:30AM0 ft. MWL - Water Level, 10 %of cross sectional area4 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR8 ft. MWL - Water Level, 40 %of cross sectional area8 ft. MWM - Water Mark, 70 %of cross sectional area18.7 ft. RFJ - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YESR - 2%25.2 ft. MWL - Water Level, 10 %of cross sectional area25.2 ft. MWM - Water Mark, 30 %of cross sectional area131.1 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YESR - 3%214 ft. MGO - General Observation - GENORATOR ON VAN STOPPED WORKING362.3 ft. AMH - Downstream Manhole, Survey Ends - 2:10AM

Observation photos (1)

  • Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR

    4 ft. - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR

Observations (12)

DistanceCodeObservation
25.2MWL
8MWL
362.3AMH2:10AM
18.7RFJ2%
0MWM
4RMJ
0AMH1:30AM
8MWM
25.2MWM
131.1RFJ3%
0MWL
214MGOGENORATOR ON VAN STOPPED WORKING

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-07-31T00:40:36-07:00
documentation
MARTIN,OLIVER 111,SHADLER
is_lateral_inspection
false