Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2019, 11:29 AM
  • Section#4_16 0278_16 0277__7302019__I0197R.mp4

Date
07/30/2019
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00654
PipeID
P13326
Time
4:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0197R
Sewer Name
16 CHAPEL AVENUE TRUNK, SECTION 3
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Maintenance Related
Project
20190730MDM_CHAPEL_AVENUE_TRUNK_SECTION_3
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
16 0278
Downstream MH
16 0277
Dir. of Survey
Downstream
Length Surveyed
328.1 ft.
Total Length
338.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 16 0278 to 16 0277
MH: 16 0278MH: 16 0277downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM0 ft. MWL - Water Level, 10 %of cross sectional area145 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN164.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN328.1 ft. AMH - Downstream Manhole, Survey Ends - 5:05AM

Observations (6)

DistanceCodeObservation
145TFOPEN
0MWM
0AMH4:45AM
0MWL
328.1AMH5:05AM
164.2TFOPEN

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-07-30T04:29:30-07:00
documentation
MARTIN,OLIVER 111,SHADLER
is_lateral_inspection
false