Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 20, 2019, 06:31 AM
  • 6_1_1_20062019_001215.mp4

Date
06/19/2019
W/O
766407
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00349
PipeID
P02967
Time
11:31 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6571
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
BELL GARDENS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
WO_766407_TV02220_MAY2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
02 1396
Downstream MH
02 1395
Dir. of Survey
Downstream
Length Surveyed
1003.5 ft.
Total Length
1003.5 ft.
Structural Index
3
Structural Quick
3c2b
Structural Rating
886
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
886
Pipe schematic from manhole 02 1396 to 02 1395
MH: 02 1396MH: 02 1395downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 139610.5 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE99.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start133.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start1000.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish1000.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1003.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1395

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    99.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    133.7 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
1000.2SSS
99.6SAV
1000.2SAV
0MWM
0MWL
0AMH02 1396
10.5MGOMAG COAT THROUGHOUT PIPE
133.7SSS
1003.5AMH02 1395

Properties (6)

additional_info
SC377696
custom_field_two
3
customer
LACSD
datetime
2019-06-19T23:31:42-07:00
documentation
PROPIPE
is_lateral_inspection
false