- Date
- 06/20/2019
- W/O
- 766407
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00349
- PipeID
- P02964
- Time
- 11:17 PM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6572
- Sewer Name
- 02 DISTRICT #2 INTERCEPTOR TRUNK
- City
- BELL GARDENS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- WO_766407_TV02220_MAY2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Width
- 54 in.
- Upstream MH
- 02 1393
- Downstream MH
- 02 1392
- Dir. of Survey
- Downstream
- Length Surveyed
- 895.7 ft.
- Total Length
- 895.7 ft.
- Structural Index
- 3
- Structural Quick
- 543b
- Structural Rating
- 551
- O&M Index
- 1
- O&M Quick
- 2117
- O&M Rating
- 9
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 560
Pipe schematic from manhole 02 1393 to 02 1392 Observation photos (4)

10 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

517.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

766.8 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

831.8 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO