Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2019, 08:38 AM
  • 19_1_1_21062019_020519.mp4

Date
06/21/2019
W/O
766407
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00349
PipeID
P02984
Time
1:38 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6572
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
BELL GARDENS
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
WO_766407_TV02220_MAY2019
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Width
63 in.
Upstream MH
02 1412
Downstream MH
02 1413
Dir. of Survey
Upstream
Length Surveyed
2.5 ft.
Total Length
2.5 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 02 1412 to 02 1413
MH: 02 1412MH: 02 1413upstream0 ft. SAP - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: NO0 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO0 ft. DAGS - Deposits Attached Grease, 0 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: NO0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG PIPE FROM D/S MH0 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO2.5 ft. MWL - Water Level, 50 %of cross sectional area2.5 ft. MWM - Water Mark, 60 %of cross sectional area2.5 ft. AMH - Downstream Manhole, Survey Begins - 02 1412

Observation photos (4)

  • Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: NO

    2.5 ft. - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: NO

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

    2.5 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Deposits Attached Grease, 0 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: NO

    2.5 ft. - Deposits Attached Grease, 0 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO

    2.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO

Observations (8)

DistanceCodeObservation
0MWL
2.5SAP
2.5SSS
2.5DAGS
0MWM
2.5MSAVIEW OF THE UPLEG PIPE FROM D/S MH
2.5SRV
0AMH02 1412

Properties (6)

additional_info
SC377697
custom_field_two
2
customer
LACSD
datetime
2019-06-21T01:38:29-07:00
documentation
PROPIPE
is_lateral_inspection
false