- Date
- 06/21/2019
- W/O
- 766407
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00349
- PipeID
- P02984
- Time
- 1:38 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6572
- Sewer Name
- 02 DISTRICT #2 INTERCEPTOR TRUNK
- City
- BELL GARDENS
- Loc. details
- Railway
- Location Code
- L
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- WO_766407_TV02220_MAY2019
- Sewer Type
- Siphon
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 63 in.
- Width
- 63 in.
- Upstream MH
- 02 1412
- Downstream MH
- 02 1413
- Dir. of Survey
- Upstream
- Length Surveyed
- 2.5 ft.
- Total Length
- 2.5 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 10
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole 02 1412 to 02 1413 Observation photos (4)

2.5 ft. - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: NO

2.5 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

2.5 ft. - Deposits Attached Grease, 0 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: NO

2.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO