Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 23, 2019, 10:18 AM
  • Section#4_18 0969_18 0968__7232019__I0186R.mp4

Date
07/23/2019
W/O
0777340
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00716
PipeID
P14819
Time
3:18 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0186R
Sewer Name
18 WORSHAM CREEK TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Maintenance Related
Project
20190723MDM_WORSHAM_CREEK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
18 0968
Downstream MH
18 0969
Dir. of Survey
Upstream
Length Surveyed
176.8 ft.
Total Length
176.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3300
O&M Rating
9
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 18 0968 to 18 0969
MH: 18 0968MH: 18 0969upstream0 ft. AMH - Upstream Manhole, Survey Ends - 3:50AM0.5 ft. MGO - General Observation - MH CONN 9:00 ACTIVE70.8 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN- 30% ROOTS129 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN-100% ROOTS136.5 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN- 90% ROOTS176.8 ft. MWL - Water Level, 5 %of cross sectional area176.8 ft. MGO - General Observation - MH CONN 3:00 ACTIVE176.8 ft. MWM - Water Mark, 20 %of cross sectional area176.8 ft. AMH - Downstream Manhole, Survey Begins - 3:30AM

Observations (9)

DistanceCodeObservation
0MWL
40.3TBDOPEN- 90% ROOTS
176.8AMH3:50AM
176.3MGOMH CONN 9:00 ACTIVE
0MGOMH CONN 3:00 ACTIVE
0MWM
47.8TBDOPEN-100% ROOTS
106TBDOPEN- 30% ROOTS
0AMH3:30AM

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-07-23T03:18:04-07:00
documentation
MARTIN,REVELES,OLIVER 111,SHADLER
is_lateral_inspection
false
lining
PVCP