Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 16, 2018, 11:39 AM
  • 01 0737_01 0736_10162018_044520.mp4

Date
10/16/2018
W/O
0734330
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00205
PipeID
P01644
Time
4:39 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1015
Sewer Name
01 COMPTON DISPOSAL TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
20
Purpose
Capital Improvement Program Assesment
Project
20181015MDM_COMPTON_DISPOSAL_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
01 0737
Downstream MH
01 0736
Dir. of Survey
Downstream
Length Surveyed
288.9 ft.
Total Length
288.9 ft.
Structural Index
4
Structural Quick
5443
Structural Rating
34
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
38
Pipe schematic from manhole 01 0737 to 01 0736
MH: 01 0737MH: 01 0736downstream0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 20% START 10:00 TO 2:002 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR POSSIBLE AT SOFFIT2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE50.5 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR103.9 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG276.4 ft. SRV - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR278.2 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR288.6 ft. MGO - General Observation - MAG COAT 20% FINISH288.6 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG288.6 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG288.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - BISTERING CONCRETE288.9 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observation photos (8)

  • General Observation - MAG COAT 20% START 10:00 TO 2:00

    2 ft. - General Observation - MAG COAT 20% START 10:00 TO 2:00

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR POSSIBLE AT SOFFIT

    2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR POSSIBLE AT SOFFIT

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE

  • Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    50.5 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG

    103.9 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    276.4 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    278.2 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

Observations (18)

DistanceCodeObservation
50.5SRVCIRCUM REBAR
2SAMSEVERE AGG
288.6MGOMAG COAT 20% FINISH
288.6SAMSEVERE AGG
0MWM
288.9AMH5:15AM
2MGOMAG COAT 20% START 10:00 TO 2:00
0MWL
0AMH4:45AM
103.9SAMSEVERE AGG
278.2SRVCIRCUM REBAR
276.4SRVCIRCUM REBAR
288.6SAMSEVERE AGG
2SAMSEVERE AGG
0MGOConn. @ Mh, 3 O' Clock. Capped
288.6SSSBISTERING CONCRETE
2SRVCIRCUM REBAR POSSIBLE AT SOFFIT
2SSSBLISTERING CONCRETE

Properties (6)

custom_field_three
CIRCUM REBAR VISIBLE SPORATIC
custom_field_two
2
customer
LACSD
datetime
2018-10-16T04:39:56-07:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false