Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 17, 2016, 07:00 AM
  • 03 0367_03 0366_20160517_001435.mp4

Date
05/17/2016
W/O
557879
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00381
PipeID
P05166
Time
12:00 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3378
Sewer Name
03 MARINA RELIEF TRUNK, SECTION 1B
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Routine Assessment
Project
WO_557879_TV03013_MARCH2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
27 in.
Upstream MH
03 0367
Downstream MH
03 0366
Dir. of Survey
Downstream
Length Surveyed
328.1 ft.
Total Length
328.1 ft.
Structural Index
2
Structural Quick
2400
Structural Rating
8
O&M Index
3
O&M Quick
4134
O&M Rating
16
Overall Index
3
Overall Quick
Overall Rating
24
Pipe schematic from manhole 03 0367 to 03 0366
MH: 03 0367MH: 03 0366downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 03 03673.7 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES4.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES49.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"85.3 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES91.8 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES92.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"110 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES110 ft. ID - Infiltration Dripper, from 10 to 12 o'clock, within 8 inches of joint: YES130.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"191.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"233 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES233 ft. IS - Infiltration Stain, from 03 to 04 o'clock, within 8 inches of joint: YES244.5 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES244.5 ft. IR - Infiltration Runner, at 11 o'clock, within 8 inches of joint: YES264.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"328.1 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK328.1 ft. AMH - Downstream Manhole, Survey Ends - 03 0366

Observation photos (10)

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    3.7 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    4.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    85.3 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    91.8 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    110 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, from 10 to 12 o'clock, within 8 inches of joint: YES

    110 ft. - Infiltration Dripper, from 10 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    233 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Infiltration Stain, from 03 to 04 o'clock, within 8 inches of joint: YES

    233 ft. - Infiltration Stain, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    244.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 11 o'clock, within 8 inches of joint: YES

    244.5 ft. - Infiltration Runner, at 11 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0MWM
233CL
91.8ID
328.1MGOCONNECTION AT MH 3 OCLOCK
244.5CL
110CL
264.1TF
4.7CL
328.1AMH03 0366
0MWL
233IS
244.5IR
0AMH03 0367
92.9TF
110ID
3.7ID
130.2TF
49.6TF
85.3ID
191.9TF

Properties (6)

additional_info
SC300377
custom_field_two
3
customer
LACSD
datetime
2016-05-17T00:00:02-07:00
documentation
PROPIPE
is_lateral_inspection
false