Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 7, 2018, 09:49 AM
  • B 0442_B 0441 _07062018_030244.mp4

Date
06/07/2018
W/O
706794
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00093
PipeID
P08954
Time
2:49 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5690
Sewer Name
B JOINT OUTFALL B - UNIT 5C
City
PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
WO_706794_TV16033_JUN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
B 0442
Downstream MH
B 0441
Dir. of Survey
Downstream
Length Surveyed
389.6 ft.
Total Length
389.6 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
231
O&M Index
1
O&M Quick
1300
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
234
Pipe schematic from manhole B 0442 to B 0441
MH: B 0442MH: B 0441downstream0 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH0 ft. AMH - Upstream Manhole, Survey Begins - B 04420 ft. MGO - General Observation - CAPPED LATERAL 3 O'CLOCK @ MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start217.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES232.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"239.7 ft. RFJ - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YES281.8 ft. RFJ - Roots Fine Joint, from 08 to 12 o'clock, within 8 inches of joint: YES317.8 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"389.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish389.6 ft. AMH - Downstream Manhole, Survey Ends - B 0441389.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

    217.6 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MGOCAPPED LATERAL 9 O'CLOCK @ MH
0AMHB 0442
389.6SAV
0MGOCAPPED LATERAL 3 O'CLOCK @ MH
389.6AMHB 0441
239.7RFJ
281.8RFJ
2.9SAV
0MWL
232.2TF
317.8TF
389.6MGOCONNECTION AT MH 3 O'CLOCK
217.6RFJ
0MWM

Properties (6)

additional_info
SC359349
custom_field_two
3
customer
LACSD
datetime
2018-06-07T02:49:12-07:00
documentation
PROPIPE
is_lateral_inspection
false