Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2018, 10:43 AM
  • 21 0903_21 0902 _05062018_040457.mp4

Date
06/05/2018
W/O
706726
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00775
PipeID
P15978
Time
3:43 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5637
Sewer Name
21 LA VERNE-"B" STREET TRUNK
City
LA VERNE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
02
Purpose
Routine Assessment
Project
WO_706726_TV21090_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
21 0903
Downstream MH
21 0902
Dir. of Survey
Downstream
Length Surveyed
394 ft.
Total Length
394 ft.
Structural Index
3
Structural Quick
3622
Structural Rating
22
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
22
Pipe schematic from manhole 21 0903 to 21 0902
MH: 21 0903MH: 21 0902downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 21 090331.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"49.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES60.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES81.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"103.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES113.3 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES131.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"167 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES170.5 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES181.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"223.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES235.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"263.4 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES285.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"335.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"385.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"394 ft. AMH - Downstream Manhole, Survey Ends - 21 0902

Observation photos (8)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    49.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    60.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

    103.3 ft. - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    113.3 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES

    167 ft. - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    170.5 ft. - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    223.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    263.4 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0MWM
385.1TFC
170.5CM
131.9TFC
223.9CM
60.1CM
103.3FC
0MWL
167FC
181.9TFC
49.8CM
235.3TFC
285.1TFC
31.5TFC
263.4CM
394AMH21 0902
81.8TFC
0AMH21 0903
335.2TFC
113.3CM

Properties (6)

additional_info
SC359192
custom_field_two
3
customer
LACSD
datetime
2018-06-05T03:43:36-07:00
documentation
PRO-PIPE
is_lateral_inspection
false