Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2018, 08:07 AM
  • 22 0626_22 0625 _05062018_012510.mp4

Date
06/05/2018
W/O
701523
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00827
PipeID
P16974
Time
1:07 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5635
Sewer Name
22 SUNFLOWER TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
21
Purpose
Routine Assessment
Project
WO_701523_TV22166_MAY2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0626
Downstream MH
22 0625
Dir. of Survey
Downstream
Length Surveyed
319.4 ft.
Total Length
319.4 ft.
Structural Index
4
Structural Quick
534C
Structural Rating
93
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
93
Pipe schematic from manhole 22 0626 to 22 0625
MH: 22 0626MH: 22 0625downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 06260 ft. MWM - Water Mark, 35 %of cross sectional area2.1 ft. SAM - Surface Aggregate Missing, from 10 to 05 o'clock, within 8 inches of joint: YES2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start5 ft. SMW - Surface Missing Wall, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - POSSIBLE8.6 ft. HSV - Hole Soil Visible, from 08 to 09 o'clock, within 8 inches of joint: NO9 ft. SMW - Surface Missing Wall, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - POSSIBLE68.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"79.4 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start117.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"166.7 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish211.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"272.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Fine Roots inside, 5%316.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish319.4 ft. AMH - Downstream Manhole, Survey Ends - 22 0625

Observation photos (4)

  • Surface Aggregate Missing, from 10 to 05 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Missing, from 10 to 05 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Hole Soil Visible, from 08 to 09 o'clock, within 8 inches of joint: NO

    8.6 ft. - Hole Soil Visible, from 08 to 09 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    79.4 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

Observations (16)

DistanceCodeObservation
117.8TFC
5SMWPOSSIBLE
2.1SAM
79.4SAM
8.6HSV
9SMWPOSSIBLE
0MWL
166.7SAM
272.5TFFine Roots inside, 5%
0AMH22 0626
316.6SAP
2.1SAP
319.4AMH22 0625
211.3TF
68.6TF
0MWM

Properties (6)

additional_info
SC359190
custom_field_two
1
customer
LACSD
datetime
2018-06-05T01:07:58-07:00
documentation
PRO PIPE
is_lateral_inspection
false