Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 6, 2017, 05:02 AM
  • J 0374_J 0150 _05092017_220524.mp4

Date
09/05/2017
W/O
651864
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00052
PipeID
P11385
Time
10:02 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4858
Sewer Name
J JOINT OUTFALL J - UNIT 1A
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
40
Purpose
Routine Assessment
Project
WO_651864_TV05159_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
J 0374
Downstream MH
J 0150
Dir. of Survey
Downstream
Length Surveyed
549.9 ft.
Total Length
549.9 ft.
Structural Index
3
Structural Quick
3O21
Structural Rating
245
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
247
Pipe schematic from manhole J 0374 to J 0150
MH: J 0374MH: J 0150downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 037412.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 01 o'clock, , within 8 inches of joint: YES22.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES67.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES76.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES87.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start428.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish447 ft. CC - Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES452.2 ft. CC - Crack Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES483.4 ft. CS - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES487.6 ft. CC - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES497.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start544.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish549.9 ft. AMH - Downstream Manhole, Survey Ends - J 0150

Observation photos (10)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 01 o'clock,  , within 8 inches of joint: YES

    12.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 01 o'clock, , within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    22.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    67.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    76.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    87.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES

    447 ft. - Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES

    452.2 ft. - Crack Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    483.4 ft. - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

    487.6 ft. - Crack Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    497.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
483.4CS
428.1CM
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
549.9AMHJ 0150
497.6CM
452.2CC
487.6CC
22.8CM
87.2CM
76.7CM
0MWM
12.3DAE
447CC
0AMHJ 0374
544.2CM
67.3CM

Properties (6)

additional_info
SC345917
custom_field_two
3
customer
LACSD
datetime
2017-09-05T22:02:47-07:00
documentation
PROPIPE
is_lateral_inspection
false