Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 15, 2017, 06:48 AM
  • 15 0065_15 0064 _02142017_224903.mp4

Date
02/14/2017
W/O
619008
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00624
PipeID
P11959
Time
10:48 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4242
Sewer Name
15 PUENTE RELIEF TRUNK
City
INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
WO_619008_TV15024_FEB2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0065
Downstream MH
15 0064
Dir. of Survey
Downstream
Length Surveyed
371.9 ft.
Total Length
371.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412N
O&M Rating
152
Overall Index
2
Overall Quick
Overall Rating
152
Pipe schematic from manhole 15 0065 to 15 0064
MH: 15 0065MH: 15 0064downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 4 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 15 00652 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start22.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"91.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"169.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"370 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish370 ft. MGO - General Observation - COCKROACHES IN MANHOLE371.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0064

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWM
22.4TFC
91.1TFC
0MWL
370DAGS
370MGOCOCKROACHES IN MANHOLE
2DAGS
0MGOACTIVE CONNECTION AT MH 4 O'CLOCK
0AMH15 0065
169.5TFC
371.9AMH15 0064

Properties (6)

additional_info
SC306745
custom_field_two
4
customer
LACSD
datetime
2017-02-14T22:48:24-08:00
documentation
PRO PIPE
is_lateral_inspection
false