Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2017, 07:19 AM
  • 02 0272_02 0271_7132017_050727.mp4

Date
07/13/2017
W/O
0647471
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00251
PipeID
P02588
Time
12:19 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0589
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
22A
Purpose
Capital Improvement Program Assesment
Project
20170710VMR_DOWNEY_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0272
Downstream MH
02 0271
Dir. of Survey
Downstream
Length Surveyed
170.1 ft.
Total Length
170.1 ft.
Structural Index
2
Structural Quick
3321
Structural Rating
17
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole 02 0272 to 02 0271
MH: 02 0272MH: 02 0271downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05:15 AM0 ft. MWL - Water Level, 20 %of cross sectional area0.4 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 8"14.7 ft. CC - Crack Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES15.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"17.2 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES25.7 ft. CC - Crack Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES29.5 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES33.8 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES37.3 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES41.9 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES53.7 ft. CC - Crack Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES57.7 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES65.9 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES119.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"170.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"

Observations (17)

DistanceCodeObservation
65.9CC
37.3CM
29.5CM
0.4TFA
14.7CC
57.7CC
119.4TFC
0MWM
0AMH05:15 AM
0MWL
53.7CC
17.2CC
41.9CM
170.1TFC
33.8CL
15.3TFC
25.7CC

Properties (4)

customer
LACSD
datetime
2017-07-13T00:19:11-07:00
documentation
REVELES,MANANES,OLIVER III
is_lateral_inspection
false