02 0012_02 0011_05062018_014652.mp4
2.9 ft. - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
4.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
16.4 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES
23.4 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO
53.6 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1"
128.4 ft. - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
181.3 ft. - Fracture Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES, Start
223.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start
303.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO
342.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO
355.2 ft. - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 137.9 | CS | — |
| 390.1 | DAE | — |
| 23.4 | DAGS | — |
| 303.2 | CL | — |
| 196.3 | FS | — |
| 143.4 | TBC | — |
| 355.2 | CS | — |
| 390.1 | DAGS | — |
| 24.2 | TBA | — |
| 0 | MWM | — |
| 16.4 | FM | — |
| 4.2 | DAGS | — |
| 180.2 | TB | — |
| 181.3 | FS | — |
| 0 | MWL | — |
| 223.3 | DAE | — |
| 391.4 | MGO | SERVICE CONNECTION AT 3 O' CLOCK AT MH |
| 128.4 | CS | — |
| 390.1 | CS | — |
| 302.3 | TB | — |
| 391.4 | MGO | SERVICE CONNECTION AT 9 O'CLOCK AT MH |
| 53.6 | TBI | — |
| 0 | AMH | 02 0011 |
| 342.2 | TBC | — |
| 2.9 | FS | — |
| 342.9 | CL | — |
| 391.4 | AMH | 02 0012 |
| 128.4 | FS | — |