Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 23, 2017, 07:09 AM
  • B 0016_B 0925_23052017_234054.mp4

Date
05/23/2017
W/O
635465
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00072
PipeID
P20088
Time
12:09 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4504
Sewer Name
B JOINT OUTFALL B - UNIT 1A
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
14
Purpose
Routine Assessment
Project
WO_635465_TV30027_MAY2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
144 in.
Width
144 in.
Upstream MH
B 0016
Downstream MH
B 0925
Dir. of Survey
Downstream
Length Surveyed
17.5 ft.
Total Length
17.5 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole B 0016 to B 0925
MH: B 0016MH: B 0925downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 00160 ft. MWL - Water Level, 35 %of cross sectional area2.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES17.5 ft. AMH - Downstream Manhole, Survey Ends - B 0925

Observation photos (1)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
2.1SRV
0AMHB 0016
2.1SAP
17.5AMHB 0925
0MWL

Properties (7)

additional_info
SC345314
custom_field_two
2
customer
LACSD
datetime
2017-05-23T00:09:10-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
33381