Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2019, 12:16 PM
  • Section#6_16 0272_16 0266__7222019__I0185R.mp4

Date
07/22/2019
W/O
0777342
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00652
PipeID
P13314
Time
5:16 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0185R
Sewer Name
16 CHAPEL AVENUE TRUNK, SECTION 1
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Maintenance Related
Project
20190722MDM_CHAPEL_AVENUE_TRUNK_SECTION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
16 0272
Downstream MH
16 0266
Dir. of Survey
Downstream
Length Surveyed
233.8 ft.
Total Length
233.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
413B
O&M Rating
60
Overall Index
3
Overall Quick
Overall Rating
60
Pipe schematic from manhole 16 0272 to 16 0266
MH: 16 0272MH: 16 0266downstream0 ft. AMH - Upstream Manhole, Survey Begins - 5:20AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.1 ft. RMJ - Roots Medium Joint, from 03 to 05 o'clock, 5 %, within 8 inches of joint: YESR8.4 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE-90% ROOTS8.4 ft. RFL - Roots Fine Lateral, from 08 to 12 o'clock - 4%25.2 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN-99% ROOTS25.2 ft. RBL - Roots Ball Lateral, from 12 to 07 o'clock, 55 %, within 8 inches of joint: YES39.2 ft. RMJ - Roots Medium Joint, from 03 to 05 o'clock, 5 %, within 8 inches of joint: YESR45.1 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR - 4%49.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN52.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN70.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 4%76.2 ft. TBD - Tap Break-In Defective, at 11 o'clock, -, , within 8 inches of joint: YES, 6" - OPEN-99% ROOTS76.2 ft. RML - Roots Medium Lateral, from 07 to 12 o'clock, 35 %, within 8 inches of joint: YES78.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN103.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN111.6 ft. RMJ - Roots Medium Joint, from 02 to 04 o'clock, 5 %, within 8 inches of joint: YESR124.2 ft. RMJ - Roots Medium Joint, from 02 to 05 o'clock, 10 %, within 8 inches of joint: YESR126.8 ft. RMJ - Roots Medium Joint, from 02 to 05 o'clock, 10 %, within 8 inches of joint: YESR127.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN137.6 ft. RMJ - Roots Medium Joint, from 07 to 10 o'clock, 10 %, within 8 inches of joint: YESR156.4 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR - 3%166.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN180.4 ft. RMJ - Roots Medium Joint, from 02 to 05 o'clock, 15 %, within 8 inches of joint: YESR197.7 ft. RMJ - Roots Medium Joint, from 03 to 09 o'clock, 5 %, within 8 inches of joint: YESR206.3 ft. RMJ - Roots Medium Joint, from 03 to 09 o'clock, 5 %, within 8 inches of joint: YESR209.4 ft. RMJ - Roots Medium Joint, from 02 to 10 o'clock, 20 %, within 8 inches of joint: YESR216.2 ft. RMJ - Roots Medium Joint, from 02 to 10 o'clock, 10 %, within 8 inches of joint: YESR221 ft. RMJ - Roots Medium Joint, from 02 to 10 o'clock, 20 %, within 8 inches of joint: YESR225.4 ft. RMJ - Roots Medium Joint, from 02 to 10 o'clock, 10 %, within 8 inches of joint: YESR233 ft. RMJ - Roots Medium Joint, from 07 to 11 o'clock, 5 %, within 8 inches of joint: YESR233.8 ft. AMH - Downstream Manhole, Survey Ends - 5:45AM

Observation photos (3)

  • Roots Ball Lateral, from 12 to 07 o'clock, 55 %, within 8 inches of joint: YES

    25.2 ft. - Roots Ball Lateral, from 12 to 07 o'clock, 55 %, within 8 inches of joint: YES

  • Tap Break-In Defective, at 11 o'clock, -,  , within 8 inches of joint: YES, 6" - OPEN-99% ROOTS

    76.2 ft. - Tap Break-In Defective, at 11 o'clock, -, , within 8 inches of joint: YES, 6" - OPEN-99% ROOTS

  • Roots Medium Lateral, from 07 to 12 o'clock, 35 %, within 8 inches of joint: YES

    76.2 ft. - Roots Medium Lateral, from 07 to 12 o'clock, 35 %, within 8 inches of joint: YES

Observations (33)

DistanceCodeObservation
124.2RMJ
25.2TFDOPEN-99% ROOTS
103.4TFOPEN
225.4RMJ
216.2RMJ
2.1RMJ
39.2RMJ
111.6RMJ
78.9TFOPEN
209.4RMJ
0AMH5:20AM
137.6RMJ
52.9TFOPEN
206.3RMJ
45.1RFJ4%
25.2RBL
233RMJ
221RMJ
70.4RFJ4%
49.6TBOPEN
233.8AMH5:45AM
0MWM
180.4RMJ
0MWL
8.4TFDACTIVE-90% ROOTS
126.8RMJ
166.4TFOPEN
76.2TBDOPEN-99% ROOTS
76.2RML
8.4RFL4%
156.4RFJ3%
127.3TFOPEN
197.7RMJ

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-07-22T05:16:58-07:00
documentation
MARTIN,REVELES,OLIVER 111,SHADLER
is_lateral_inspection
false