Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2019, 10:10 AM
  • Section#1_18 0944_18 0943__7192019__I0181.mp4

Date
07/19/2019
W/O
0777341
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00701
PipeID
P14791
Time
3:10 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0181R
Sewer Name
18 SCOTT AVENUE RELIEF TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Maintenance Related
Project
20190719MDM_SCOTT_AVENUE_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
18 0944
Downstream MH
18 0943
Dir. of Survey
Downstream
Length Surveyed
262.8 ft.
Total Length
262.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0944 to 18 0943
MH: 18 0944MH: 18 0943downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:25AM8 ft. MWM - Water Mark, 30 %of cross sectional area105 ft. MGO - General Observation - 7.5" VCP+ PVCP181.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN262.8 ft. AMH - Downstream Manhole, Survey Ends - 3:45AM

Observation photos (1)

  • General Observation - 7.5" VCP+ PVCP

    105 ft. - General Observation - 7.5" VCP+ PVCP

Observations (6)

DistanceCodeObservation
105MGO7.5" VCP+ PVCP
0MWL
0AMH3:25AM
262.8AMH3:45AM
8MWM
181.9TBOPEN

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-07-19T03:10:25-07:00
documentation
MARTIN,REVELES,OLIVER 111,SHADLER
is_lateral_inspection
false
lining
PVCP-Folded/Reformed