Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 19, 2019, 03:42 PM
  • A 0303_A 1226_7192019_103634.mp4

Date
07/19/2019
W/O
0767441
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00325
PipeID
P21654
Time
8:42 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8033
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
WHITTIER
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
20190719DF_JOA_1A_SAN_JOSE_CREEK_WRP_INT
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
A 0303
Downstream MH
A 1226
Dir. of Survey
Downstream
Length Surveyed
643.3 ft.
Total Length
643.3 ft.
Structural Index
4
Structural Quick
5232
Structural Rating
18
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
18
Pipe schematic from manhole A 0303 to A 1226
MH: A 0303MH: A 1226downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:00 AM0.1 ft. MWM - Water Mark, 30 %of cross sectional area0.1 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start43.7 ft. MGP - General Photograph68.7 ft. MGP - General Photograph102.6 ft. MGP - General Photograph255.1 ft. MGP - General Photograph334.4 ft. MGP - General Photograph562.1 ft. MGP - General Photograph600 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start618.2 ft. MGP - General Photograph629.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start634.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start641 ft. MGP - General Photograph643.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish643.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish643.2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish643.2 ft. MGP - General Photograph643.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish643.2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 75% MAG643.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish643.3 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)643.3 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach643.3 ft. AMH - Downstream Manhole, Survey Ends - 11:18 AM

Observation photos (14)

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    43.7 ft. - General Photograph

  • General Photograph

    68.7 ft. - General Photograph

  • General Photograph

    102.6 ft. - General Photograph

  • General Photograph

    255.1 ft. - General Photograph

  • General Photograph

    334.4 ft. - General Photograph

  • General Photograph

    562.1 ft. - General Photograph

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    600 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    618.2 ft. - General Photograph

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    629.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    634.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    641 ft. - General Photograph

  • General Photograph

    643.2 ft. - General Photograph

Observations (27)

DistanceCodeObservation
0.1MWM
643.2SSS
618.2MGP
0AMH10:00 AM
68.7MGP
334.4MGP
255.1MGP
643.3MGOGREASE THROUGHOUT THE REACH (5%)
634.8SAP
643.2SRC
629.5SAV
643.3MGOPeeling & Flaking Throughout The Reach
641MGP
562.1MGP
0.1MWL
643.2SRV
2SSS
600SRC
643.3AMH11:18 AM
2SZ75% MAG
643.2MGP
643.2SAP
643.2SZ75% MAG
43.7MGP
643.2SAV
102.6MGP
2SRV

Properties (6)

custom_field_two
3
customer
LACSD
datetime
2019-07-19T08:42:10-07:00
documentation
FRANKLIN, CASTILLO, IGNACIO, RUVALCABA
is_lateral_inspection
false
year_laid
19790427