Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2019, 09:58 AM
  • 4_1_2_11062019_030222.mp4

Date
06/11/2019
W/O
766606
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13896
Time
2:58 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6563
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_766606_TV18177_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 1096
Downstream MH
18 0078
Dir. of Survey
Upstream
Length Surveyed
19.2 ft.
Total Length
19.2 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 18 1096 to 18 0078
MH: 18 1096MH: 18 0078upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 00781.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish16.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19.2 ft. MWM - Water Mark, 25 %of cross sectional area19.2 ft. AMH - Downstream Manhole, Survey Begins - 18 109619.2 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK CAPPED19.2 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWM
3SAP
18.1SAP
0AMH18 1096
0MGOCONNECTION IN MH 3 OCLOCK CAPPED
0MWL
19.2AMH18 0078

Properties (6)

additional_info
SC377686
custom_field_two
3
customer
LACSD
datetime
2019-06-11T02:58:14-07:00
documentation
PROPIPE
is_lateral_inspection
false