Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2019, 04:59 AM
  • 19_1_1_10062019_221113.mp4

Date
06/10/2019
W/O
766606
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13925
Time
9:59 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6563
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_766606_TV18177_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0105
Downstream MH
18 0104
Dir. of Survey
Downstream
Length Surveyed
170.8 ft.
Total Length
170.8 ft.
Structural Index
3
Structural Quick
3F00
Structural Rating
99
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
99
Pipe schematic from manhole 18 0105 to 18 0104
MH: 18 0105MH: 18 0104downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01053.6 ft. MWM - Water Mark, 45 %of cross sectional area4.6 ft. MGO - General Observation - HEAVY SPLASHING DUE TO HEAVY CURRENT4.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start22.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"37.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"40.1 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"67.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"70.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"118.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"121.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"168.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish170.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0104170.8 ft. MGO - General Observation - CONNECTION IN MH 9 AND 3 OCLOCK CAPPED

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
67.6TF
4.6MGOHEAVY SPLASHING DUE TO HEAVY CURRENT
168.5SAP
70.2TF
40.1TB
4.6SAP
118.7TFC
0MWL
0AMH18 0105
22.4TF
121.5TFC
170.8AMH18 0104
3.6MWM
170.8MGOCONNECTION IN MH 9 AND 3 OCLOCK CAPPED
37.3TF

Properties (6)

additional_info
SC377686
custom_field_two
3
customer
LACSD
datetime
2019-06-10T21:59:07-07:00
documentation
PROPIPE
is_lateral_inspection
false