Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2019, 10:53 AM
  • 9_1_1_04062019_041010.mp4

Date
06/04/2019
W/O
766606
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00698
PipeID
P13907
Time
3:53 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6070
Sewer Name
18 SANTA FE STREET TRUNK
City
WITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_766606_TV18177_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0088
Downstream MH
18 0087
Dir. of Survey
Downstream
Length Surveyed
223.3 ft.
Total Length
223.3 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
132
O&M Index
3
O&M Quick
4123
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
142
Pipe schematic from manhole 18 0088 to 18 0087
MH: 18 0088MH: 18 0087downstream0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 00880 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start6.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES9.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES37.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 01 to 03 o'clock, , within 8 inches of joint: YES50.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"151.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"220.3 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish223.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0087

Observation photos (4)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock,  , within 8 inches of joint: YES

    6.8 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock,  , within 8 inches of joint: YES

    9.9 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 01 to 03 o'clock,  , within 8 inches of joint: YES

    37.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 01 to 03 o'clock, , within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
37.4DAE
9.9DAE
0MGOCONNECTION IN MH 3 OCLOCK
0AMH18 0088
2SAV
151.1TFC
220.3SAV
6.8DAE
0MWL
50.7TFC
223.3AMH18 0087
0MWM

Properties (6)

additional_info
SC377914
custom_field_two
3
customer
LACSD
datetime
2019-06-04T03:53:23-07:00
documentation
PRO PIPE
is_lateral_inspection
false