Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2019, 06:47 AM
  • 14_1_2_10062019_235504.mp4

Date
06/10/2019
W/O
766606
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13920
Time
11:47 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6563
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_766606_TV18177_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0100
Downstream MH
18 0099
Dir. of Survey
Downstream
Length Surveyed
100.8 ft.
Total Length
100.8 ft.
Structural Index
3
Structural Quick
413C
Structural Rating
61
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
65
Pipe schematic from manhole 18 0100 to 18 0099
MH: 18 0100MH: 18 0099downstream0 ft. MGO - General Observation - HEAVY SPLASHING DUE TO FLOW VELOCITY0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01002.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"11.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"53.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"56.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"87.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.8 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES99.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish100.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0099

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MGOHEAVY SPLASHING DUE TO FLOW VELOCITY
91.8FM
56.8TF
8.5TFC
87.2TF
100.8AMH18 0099
11.3TF
0MWM
53.9TF
0MWL
0AMH18 0100
99.6SAP
2.6SAP

Properties (6)

additional_info
SC377686
custom_field_two
3
customer
LACSD
datetime
2019-06-10T23:47:06-07:00
documentation
PROPIPE
is_lateral_inspection
false