Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2019, 09:01 AM
  • 8_1_1_04062019_021210.mp4

Date
06/04/2019
W/O
766606
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00698
PipeID
P13904
Time
2:01 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6070
Sewer Name
18 SANTA FE STREET TRUNK
City
Wittier
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_766606_TV18177_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0085
Downstream MH
18 0084
Dir. of Survey
Downstream
Length Surveyed
284 ft.
Total Length
284 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
159
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
159
Pipe schematic from manhole 18 0085 to 18 0084
MH: 18 0085MH: 18 0084downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 008516.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start108.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"181.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"279.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish284 ft. AMH - Downstream Manhole, Survey Ends - 18 0084

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
279.9SAV
0MWM
16.1SAV
181.7TFC
284AMH18 0084
108.7TFC
0AMH18 0085

Properties (6)

additional_info
SC377914
custom_field_two
3
customer
LACSD
datetime
2019-06-04T02:01:34-07:00
documentation
PRO PIPE
is_lateral_inspection
false