- Date
- 06/11/2019
- W/O
- 766606
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00698
- PipeID
- P13892
- Time
- 2:21 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6563
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_766606_TV18177_MAY2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0076
- Downstream MH
- 18 0075A
- Dir. of Survey
- Downstream
- Length Surveyed
- 137.7 ft.
- Total Length
- 137.7 ft.
- Structural Index
- 3
- Structural Quick
- 3D00
- Structural Rating
- 78
- O&M Index
- 2
- O&M Quick
- 412I
- O&M Rating
- 102
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 180
Pipe schematic from manhole 18 0076 to 18 0075A Observation photos (4)

3.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

3.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

19 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

52.6 ft. - Infiltration Runner, at 08 o'clock, within 8 inches of joint: YES