Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2019, 09:08 AM
  • 2_1_1_11062019_021941.mp4

Date
06/11/2019
W/O
766606
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00698
PipeID
P13893
Time
2:08 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6563
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_766606_TV18177_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0425
Downstream MH
18 0076
Dir. of Survey
Downstream
Length Surveyed
220.9 ft.
Total Length
220.9 ft.
Structural Index
3
Structural Quick
3H2H
Structural Rating
215
O&M Index
2
O&M Quick
312M
O&M Rating
147
Overall Index
2
Overall Quick
Overall Rating
362
Pipe schematic from manhole 18 0425 to 18 0076
MH: 18 0425MH: 18 0076downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 04250 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - ROPE TIED AT MH0 ft. MGO - General Observation - CONNECTION IN MH 9 OCLOCK W/ STOP LOG0 ft. MWL - Water Level, 15 %of cross sectional area3.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start36.2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES62.7 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES78.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start157.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"219.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish219.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish219.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish219.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish220.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0076

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    36.2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    62.7 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    78.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
219.3SAP
157.2TFA
219.3SSS
0AMH18 0425
3.8DAGS
62.7ID
0MWM
219.3DAE
0MGOROPE TIED AT MH
3.8SSS
36.2DAE
220.9AMH18 0076
219.3DAGS
0MGOCONNECTION IN MH 9 OCLOCK W/ STOP LOG
78.1DAE
3.8SAP
0MWL

Properties (6)

additional_info
SC377686
custom_field_two
2
customer
LACSD
datetime
2019-06-11T02:08:16-07:00
documentation
PROPIPE
is_lateral_inspection
false