Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 19, 2019, 07:34 AM
  • 7_1_1_19042019_005013.mp4

Date
04/19/2019
W/O
761615
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00689
PipeID
P13860
Time
12:34 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6521
Sewer Name
18 MILLS AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_761615_TV18176_APR2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0044A
Downstream MH
18 0044
Dir. of Survey
Downstream
Length Surveyed
283.6 ft.
Total Length
283.6 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
16
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 18 0044A to 18 0044
MH: 18 0044AMH: 18 0044downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 18 0044A0 ft. MWM - Water Mark, 35 %of cross sectional area2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"10.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"71.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"78.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"119.5 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES127.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"133 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"134.8 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES178.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"181.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"183.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES229.4 ft. CS - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES233.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"239.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"281.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish283.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0044

Observation photos (5)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    119.5 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    134.8 ft. - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    183.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

    229.4 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
133TFC
4.6TFC
71.9TFC
283.6AMH18 0044
0MWL
78.1TFC
2.2SAP
229.4CS
281.3SAP
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
134.8CM
233.6TFC
239.8TFC
0AMH18 0044A
10.8TFC
178.6TFC
127.1TFC
181.9TFC
183.5FM
119.5FM
0MWM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-04-19T00:34:51-07:00
documentation
PROPIPE
is_lateral_inspection
false