Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 19, 2019, 06:29 AM
  • 13_1_1_18042019_234811.mp4

Date
04/18/2019
W/O
761615
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00689
PipeID
P13875
Time
11:29 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6521
Sewer Name
18 MILLS AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_761615_TV18176_APR2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0060
Downstream MH
18 0061
Dir. of Survey
Upstream
Length Surveyed
341.4 ft.
Total Length
341.4 ft.
Structural Index
2
Structural Quick
3224
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 18 0060 to 18 0061
MH: 18 0060MH: 18 0061upstream0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Ends - 18 00610 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish75.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"160 ft. CS - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES181.4 ft. FS - Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES205.9 ft. CS - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES205.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES207.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"221.5 ft. CS - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES247 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"286.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"314.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"316.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"335.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start341.4 ft. AMH - Downstream Manhole, Survey Begins - 18 0060341.4 ft. MWM - Water Mark, 20 %of cross sectional area341.4 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (6)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

    119.9 ft. - Crack Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

    135.5 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    135.5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

    160 ft. - Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

    181.4 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
0AMH18 0060
0MWM
341.4MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
94.4TFA
27.1TFA
265.5TFA
135.5CS
0MWL
54.5TFA
135.5CL
341.4AMH18 0061
341.4MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
134.1TFA
181.4CS
160FS
119.9CS
25.1TFA
6SAP
339.3SAP

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-04-18T23:29:36-07:00
documentation
PROPIPE
is_lateral_inspection
false