Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 2, 2019, 09:04 AM
  • 05 1164_05 1163 _05022019_022334.mp4

Date
05/02/2019
W/O
761459
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00437
PipeID
P06402
Time
2:04 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6529
Sewer Name
05 EAST ROSECRANS AVENUE TRUNK, SECTION 2
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_761459_TV05354_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
05 1163
Downstream MH
05 1164
Dir. of Survey
Upstream
Length Surveyed
340.4 ft.
Total Length
340.4 ft.
Structural Index
4
Structural Quick
4L31
Structural Rating
263
O&M Index
1
O&M Quick
311C
O&M Rating
21
Overall Index
3
Overall Quick
Overall Rating
284
Pipe schematic from manhole 05 1163 to 05 1164
MH: 05 1163MH: 05 1164upstream0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 05 11642.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.1 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish39.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"91.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"91.5 ft. RMC - Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES93.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start138.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"190.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"241.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"296.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"326.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start331.8 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES340.4 ft. AMH - Downstream Manhole, Survey Begins - 05 1163340.4 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK340.4 ft. MWL - Water Level, 20 %of cross sectional area340.4 ft. MWM - Water Mark, 35 %of cross sectional area

Observation photos (5)

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    8.6 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    246.8 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"

    248.9 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"

  • Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES

    248.9 ft. - Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
340.4MGOCONNECTION IN MH 3 OCLOCK
248.9TFC
248.9RMC
0AMH05 1163
340.4AMH05 1164
201.7TFA
98.6TFC
8.6CM
0MGOCONNECTION IN MH 3 OCLOCK
246.8RFJ
43.7TF
300.6TFC
149.8TFC
0MWL
13.5FM
338.3FM
0MWM
338.3RFJ

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-05-02T02:04:30-07:00
documentation
PROPIPE
is_lateral_inspection
false