Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2016, 09:57 AM
  • 05 1714_05 1713_20160125_020926.mp4

Date
01/25/2016
W/O
541735
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00471
PipeID
P06941
Time
1:57 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2780
Sewer Name
05 LOMITA TRUNK
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
WO_541735_TV05197_DEC2015
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
05 1714
Downstream MH
05 1713
Dir. of Survey
Downstream
Length Surveyed
289.1 ft.
Total Length
289.1 ft.
Structural Index
4
Structural Quick
4200
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 05 1714 to 05 1713
MH: 05 1714MH: 05 1713downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 17140.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES4 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start284.3 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish289.1 ft. AMH - Downstream Manhole, Survey Ends - 05 1713

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    0.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    4 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
289.1AMH05 1713
0MWL
0.6FM
284.3FM
4FM
0MWM
0AMH05 1714

Properties (7)

additional_info
SC207092
custom_field_three
FRACTURES
custom_field_two
2
customer
LACSD
datetime
2016-01-25T01:57:25-08:00
documentation
PROPIPE
is_lateral_inspection
false