05 1716_05 1715_20160125_014229.mp4
3.9 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
5.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
8 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start
8.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
23.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
34.7 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"
198.7 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 136 | TF | — |
| 0.1 | MWM | — |
| 0 | AMH | 05 1716 |
| 8.7 | CM | — |
| 34.7 | TF | — |
| 306.7 | AMH | 05 1715 |
| 198.7 | DSZ | — |
| 3.9 | CL | — |
| 23.9 | FM | — |
| 303.6 | FM | — |
| 175.3 | DSZ | — |
| 8 | DSZ | — |
| 23.9 | CM | — |
| 247.1 | TF | — |
| 5.5 | FM | — |