Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2016, 06:38 AM
  • 05 1722_05 1721_20160125_225404.mp4

Date
01/25/2016
W/O
541735
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00471
PipeID
P06949
Time
10:38 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2781
Sewer Name
05 LOMITA TRUNK
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
WO_541735_TV05197_DEC2015
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
05 1722
Downstream MH
05 1721
Dir. of Survey
Downstream
Length Surveyed
356.3 ft.
Total Length
356.3 ft.
Structural Index
3
Structural Quick
3322
Structural Rating
13
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 05 1722 to 05 1721
MH: 05 1722MH: 05 1721downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 172238.1 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES41.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start70.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"172.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish183.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"208.6 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES224.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES233.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start275.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"352.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish356.3 ft. AMH - Downstream Manhole, Survey Ends - 05 1721

Observation photos (4)

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    38.1 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    41.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    208.6 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    224.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
224.9CM
0MWM
208.6CL
183.3TF
38.1CL
172.2CM
70.9TF
356.3AMH05 1721
41.9CM
0MWL
233.7CM
275.6TF
0AMH05 1722
352.6CM

Properties (7)

additional_info
SC207093
custom_field_three
CRACKS
custom_field_two
3
customer
LACSD
datetime
2016-01-25T22:38:58-08:00
documentation
PROPIPE
is_lateral_inspection
false