Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2016, 06:15 PM
  • H 0695_H 0694_20160722_124429.mp4

Date
07/22/2016
W/O
574527
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00941
PipeID
P11102
Time
11:15 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3409
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
WO_574527_TV18074_JULY2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0695
Downstream MH
H 0694
Dir. of Survey
Downstream
Length Surveyed
747.9 ft.
Total Length
747.9 ft.
Structural Index
2
Structural Quick
2\00
Structural Rating
286
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
286
Pipe schematic from manhole H 0695 to H 0694
MH: H 0695MH: H 0694downstream0 ft. MGO - General Observation - MAG.H.C. START 60%0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 06950 ft. MWL - Water Level, 15 %of cross sectional area30 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start744 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish747.9 ft. MGO - General Observation - MAG.H.C. FINISH 60%747.9 ft. AMH - Downstream Manhole, Survey Ends - H 0694

Observation photos (1)

  • General Observation - MAG.H.C. START  60%

    0 ft. - General Observation - MAG.H.C. START 60%

Observations (8)

DistanceCodeObservation
0MGOMAG.H.C. START 60%
0MWM
30SSS
0AMHH 0695
0MWL
747.9MGOMAG.H.C. FINISH 60%
744SSS
747.9AMHH 0694

Properties (6)

additional_info
SC305954
custom_field_two
3
customer
LACSD
datetime
2016-07-22T11:15:22-07:00
documentation
PRO PIPE
is_lateral_inspection
false