Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2016, 11:46 PM
  • H 0664_H 0343_20160714_040510.mp4

Date
06/29/2016
W/O
574527
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00941
PipeID
P11071
Time
4:46 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3613
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
06
Purpose
Routine Assessment
Project
WO_574527_TV18074_JULY2016
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
28 in.
Width
28 in.
Upstream MH
H 0664
Downstream MH
H 0343
Dir. of Survey
Downstream
Length Surveyed
444.1 ft.
Total Length
444.1 ft.
Structural Index
2
Structural Quick
312P
Structural Rating
175
O&M Index
2
O&M Quick
4128
O&M Rating
20
Overall Index
2
Overall Quick
Overall Rating
195
Pipe schematic from manhole H 0664 to H 0343
MH: H 0664MH: H 0343downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 06640 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - MAG COATING 90%0 ft. MWM - Water Mark, 50 %of cross sectional area12.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LIGHT AMOUNT375.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES394.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - OTHER436 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - OTHER444 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish444.1 ft. AMH - Downstream Manhole, Survey Ends - H 0343

Observation photos (3)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LIGHT AMOUNT

    12.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LIGHT AMOUNT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    375.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - OTHER

    394.1 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - OTHER

Observations (10)

DistanceCodeObservation
0AMHH 0664
444.1AMHH 0343
375.1SAP
12.1SSSLIGHT AMOUNT
0MWL
0MGOMAG COATING 90%
436DSZOTHER
0MWM
444SSS
394.1DSZOTHER

Properties (6)

additional_info
SC305792
custom_field_two
3
customer
LACSD
datetime
2016-06-29T16:46:39-07:00
documentation
PROPIPE
is_lateral_inspection
false