Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 24, 2015, 09:05 AM
  • 05 1603_05 1602_15550224_011718.mp4

Date
02/24/2015
W/O
491476
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00551
PipeID
P06827
Time
1:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2247
Sewer Name
05 203RD STREET TRUNK
City
TORANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
27
Purpose
Routine Assessment
Project
RFIR_WO_491476_TV05176_2015FEBRUARY
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 1603
Downstream MH
05 1602
Dir. of Survey
Downstream
Length Surveyed
296.2 ft.
Total Length
296.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 1603 to 05 1602
MH: 05 1603MH: 05 1602downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 16033.3 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start20 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start20 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish51.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"103.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"154.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"162.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish209.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"266.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"296.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1602

Observation photos (13)

  • Water Mark, 5 %of cross sectional area

    0 ft. - Water Mark, 5 %of cross sectional area

  • Water Level, 5 %of cross sectional area

    0 ft. - Water Level, 5 %of cross sectional area

  • Upstream Manhole, Survey Begins - 05 1603

    0 ft. - Upstream Manhole, Survey Begins - 05 1603

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    20 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish

    20 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    51.8 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    103.1 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    154.6 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

    162.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    209.9 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    266.3 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Downstream Manhole, Survey Ends - 05 1602

    296.2 ft. - Downstream Manhole, Survey Ends - 05 1602

Observations (13)

DistanceCodeObservation
20CM
154.6TF
0MWM
20CL
162.4CM
51.8TF
296.2AMH05 1602
209.9TF
0MWL
0AMH05 1603
103.1TF
3.3CL
266.3TF

Properties (6)

additional_info
SC207522
custom_field_two
3
customer
LACSD
datetime
2015-02-24T01:05:27-08:00
documentation
PROPIPE
is_lateral_inspection
false