Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 14, 2016, 08:23 AM
  • 05 0778_05 0777_14032016_012410.mp4

Date
03/14/2016
W/O
557677
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00553
PipeID
P06006
Time
1:23 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3288
Sewer Name
05 MANCHESTER-VERMONT DIVERSION EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_557677_TV05272_2016MAR
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 0778
Downstream MH
05 0777
Dir. of Survey
Downstream
Length Surveyed
394 ft.
Total Length
394 ft.
Structural Index
4
Structural Quick
4N00
Structural Rating
308
O&M Index
2
O&M Quick
412^
O&M Rating
316
Overall Index
3
Overall Quick
Overall Rating
624
Pipe schematic from manhole 05 0778 to 05 0777
MH: 05 0778MH: 05 0777downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 07780 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start391.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish391.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish391.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish394 ft. AMH - Downstream Manhole, Survey Ends - 05 0777

Observation photos (3)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWL
394AMH05 0777
391.8FM
5.5FM
391.8DAE
2DAE
0AMH05 0778
391.8DAGS
2DAGS
0MWM

Properties (6)

additional_info
SC305412
custom_field_two
2
customer
LACSD
datetime
2016-03-14T01:23:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false