Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2015, 11:29 AM
  • 03 0325_03 0324_20151216_034148.mp4

Date
12/16/2015
W/O
531067
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00359
PipeID
P04899
Time
3:29 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2890
Sewer Name
03 ANAHEIM STREET TRUNK
City
LONG BEACH, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_531067_TV03106_DEC2015
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
30 in.
Upstream MH
03 0325
Downstream MH
03 0324
Dir. of Survey
Downstream
Length Surveyed
79 ft.
Total Length
79 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
5141
O&M Rating
29
Overall Index
2
Overall Quick
Overall Rating
29
Pipe schematic from manhole 03 0325 to 03 0324
MH: 03 0325MH: 03 0324downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 03250 ft. MWL - Water Level, 45 %of cross sectional area0.1 ft. MWM - Water Mark, 70 %of cross sectional area26.9 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start71.6 ft. OBR - Obstacles Rocks, 45 %of cross sectional area, from 04 to 08 o'clock79 ft. MSA - Survey Abandoned - DUE TO HEAVY DEBRIS IN BOTTOM OF PIPE79 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (3)

  • Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start

    26.9 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

  • Obstacles Rocks, 45 %of cross sectional area, from 04 to 08 o'clock

    71.6 ft. - Obstacles Rocks, 45 %of cross sectional area, from 04 to 08 o'clock

  • Survey Abandoned - DUE TO HEAVY DEBRIS IN BOTTOM OF PIPE

    79 ft. - Survey Abandoned - DUE TO HEAVY DEBRIS IN BOTTOM OF PIPE

Observations (7)

DistanceCodeObservation
0AMH03 0325
26.9DAGS
71.6OBR
0.1MWM
0MWL
79MSADUE TO HEAVY DEBRIS IN BOTTOM OF PIPE
79DAGS

Properties (6)

additional_info
SC224466
custom_field_two
5
customer
LACSD
datetime
2015-12-16T03:29:54-08:00
documentation
PRO-PIPE
is_lateral_inspection
false