Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 19, 2017, 10:28 AM
  • 32 1170_32 1169_19092017_033004.mp4

Date
09/19/2017
W/O
654209
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00839
PipeID
P19624
Time
3:28 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4880
Sewer Name
32 SAN FERNANDO ROAD TRUNK
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_654209_TV32039_AUG2017
Sewer Type
Gravity
Material
CIP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1170
Downstream MH
32 1169
Dir. of Survey
Downstream
Length Surveyed
410 ft.
Total Length
410 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 32 1170 to 32 1169
MH: 32 1170MH: 32 1169downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 11700 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area3 ft. MGO - General Observation - MAG COAT3 ft. MMC - Material Change, Concrete pipe (non-reinfored)3 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start211.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"215.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"344.5 ft. MMC - Material Change, Cast Iron408.4 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish410 ft. AMH - Downstream Manhole, Survey Ends - 32 1169

Observation photos (3)

  • Material Change, Concrete pipe (non-reinfored)

    3 ft. - Material Change, Concrete pipe (non-reinfored)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Cast Iron

    344.5 ft. - Material Change, Cast Iron

Observations (11)

DistanceCodeObservation
3MGOMAG COAT
408.4SAV
0AMH32 1170
410AMH32 1169
211.4TF
0MWL
3MMC
3SAV
0MWM
344.5MMC
215.2TFC

Properties (6)

additional_info
SC345940
custom_field_two
3
customer
LACSD
datetime
2017-09-19T03:28:51-07:00
documentation
PROPIPE
is_lateral_inspection
false