- Date
- 10/05/2017
- W/O
- 663354
- Weather
- Dry
- Operator/Surveyor
- JUAN B
- Sewer ID
- Z00641
- PipeID
- P13143
- Time
- 10:31 PM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K4995
- Sewer Name
- 16 ALLEN AVENUE TRUNK, SECTION 5
- City
- SAN MARINO
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- WO_663354_TV16009_OCT2017
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 16 0105
- Downstream MH
- 16 0104
- Dir. of Survey
- Downstream
- Length Surveyed
- 109.5 ft.
- Total Length
- 109.5 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2C00
- O&M Rating
- 42
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 47
Pipe schematic from manhole 16 0105 to 16 0104 Observation photos (3)

2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2.9 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - MAG COATING

2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start