Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 9, 2015, 06:30 AM
  • 16 0616_16 0615_20151208_225031.mp4

Date
12/08/2015
W/O
531059
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00664
PipeID
P13666
Time
10:30 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2843
Sewer Name
16 PASADENA EAST-WEST INTERCEPTOR TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
09
Purpose
Routine Assessment
Project
WO_531059_TV16030_OCT2015
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
16 0616
Downstream MH
16 0615
Dir. of Survey
Downstream
Length Surveyed
361.4 ft.
Total Length
361.4 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
213
O&M Index
2
O&M Quick
2M13
O&M Rating
145
Overall Index
2
Overall Quick
Overall Rating
358
Pipe schematic from manhole 16 0616 to 16 0615
MH: 16 0616MH: 16 0615downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Begins - 16 06162.3 ft. MGO - General Observation - MAGNEZIUM H.O. START2.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start80.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - LIGHT DEBRIS INSIDE136.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"150.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"233.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - LIGHT DEBRIS INSIDE233.4 ft. VC - Vermin Cockroach355.8 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH355.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish355.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish361.4 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE361.4 ft. AMH - Downstream Manhole, Survey Ends - 16 0615361.4 ft. VC - Vermin Cockroach

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - LIGHT DEBRIS INSIDE

    80.8 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - LIGHT DEBRIS INSIDE

Observations (19)

DistanceCodeObservation
2.3MGOMAGNEZIUM H.O. START
80.8TFLIGHT DEBRIS INSIDE
2.3SAV
136.5TF
150.3TF
361.4MGOLATERAL AT MH 9 OCLOCK ACTIVE
2.3DAGS
361.4AMH16 0615
0MWM
233.4TFLIGHT DEBRIS INSIDE
233.4VC
355.8MGOMAGNEZIUM H.O. FINISH
0MGOLATERAL AT MH 9 OCLOCK ACTIVE
355.8SAV
0MWL
355.8DAGS
0VC
0AMH16 0616
361.4VC

Properties (6)

additional_info
SC205697
custom_field_two
3
customer
LACSD
datetime
2015-12-08T22:30:30-08:00
documentation
PRO PIPE
is_lateral_inspection
false