Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 9, 2015, 07:33 AM
  • 16 0613_16 0612_20151208_233814.mp4

Date
12/08/2015
W/O
531059
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00664
PipeID
P13663
Time
11:33 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2843
Sewer Name
16 PASADENA EAST-WEST INTERCEPTOR TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
09
Purpose
Routine Assessment
Project
WO_531059_TV16030_OCT2015
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
16 0613
Downstream MH
16 0612
Dir. of Survey
Downstream
Length Surveyed
29.1 ft.
Total Length
29.1 ft.
Structural Index
3
Structural Quick
3500
Structural Rating
15
O&M Index
2
O&M Quick
2212
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
21
Pipe schematic from manhole 16 0613 to 16 0612
MH: 16 0613MH: 16 0612downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Begins - 16 06130 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. MGO - General Observation - MAGNEZIUM H.O. START25.4 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH25.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish25.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish29.1 ft. VC - Vermin Cockroach29.1 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE29.1 ft. AMH - Downstream Manhole, Survey Ends - 16 0612

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
0MWL
0MWM
25.4MGOMAGNEZIUM H.O. FINISH
2.2DAGS
2.3MGOMAGNEZIUM H.O. START
0VC
29.1VC
25.4DAGS
29.1MGOLATERAL AT MH 9 OCLOCK ACTIVE
2.2SAV
0AMH16 0613
0MGOLATERAL AT MH 9 OCLOCK ACTIVE
25.4SAV
29.1AMH16 0612

Properties (6)

additional_info
SC205697
custom_field_two
3
customer
LACSD
datetime
2015-12-08T23:33:14-08:00
documentation
PRO PIPE
is_lateral_inspection
false