Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 9, 2015, 07:41 AM
  • 16 0612_16 0611_20151209_000118.mp4

Date
12/08/2015
W/O
531059
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00664
PipeID
P13662
Time
11:41 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2843
Sewer Name
16 PASADENA EAST-WEST INTERCEPTOR TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
09
Purpose
Routine Assessment
Project
WO_531059_TV16030_OCT2015
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Upstream MH
16 0612
Downstream MH
16 0611
Dir. of Survey
Downstream
Length Surveyed
414.4 ft.
Total Length
414.4 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
246
O&M Index
2
O&M Quick
2O13
O&M Rating
167
Overall Index
2
Overall Quick
Overall Rating
413
Pipe schematic from manhole 16 0612 to 16 0611
MH: 16 0612MH: 16 0611downstream0 ft. AMH - Upstream Manhole, Survey Begins - 16 06120 ft. VC - Vermin Cockroach0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. MGO - General Observation - MAGNEZIUM H.O. START2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start133.8 ft. VC - Vermin Cockroach133.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - LIGHT DEBRIS INSIDE253.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS INSIDE LIGHT359 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"410.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish410.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish410.3 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH414.4 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK ACTIVE414.4 ft. AMH - Downstream Manhole, Survey Ends - 16 0611414.4 ft. VC - Vermin Cockroach

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
2.5SAV
133.8VC
410.3SAV
133.8TFLIGHT DEBRIS INSIDE
0AMH16 0612
414.4MGOLATERAL AT MH 9 OCLOCK ACTIVE
0VC
253.7TFDEBRIS INSIDE LIGHT
410.3DAGS
0MGOLATERAL AT MH 9 OCLOCK ACTIVE
0MWM
410.3MGOMAGNEZIUM H.O. FINISH
2.5MGOMAGNEZIUM H.O. START
414.4AMH16 0611
359TFA
0MWL
2.5DAGS
414.4VC

Properties (6)

additional_info
SC205697
custom_field_two
3
customer
LACSD
datetime
2015-12-08T23:41:44-08:00
documentation
PRO PIPE
is_lateral_inspection
false