- Date
- 11/29/2017
- W/O
- 0674089
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00471
- PipeID
- P06921
- Time
- 2:14 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0685
- Sewer Name
- 05 LOMITA TRUNK
- City
- LOMITA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 33
- Purpose
- Capital Improvement Program Assesment
- Project
- 20171127MDM_LOMITA_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 05 1694
- Downstream MH
- 05 1695
- Dir. of Survey
- Upstream
- Length Surveyed
- 331.7 ft.
- Total Length
- 331.7 ft.
- Structural Index
- 2
- Structural Quick
- 372C
- Structural Rating
- 57
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 57
Pipe schematic from manhole 05 1694 to 05 1695 Observation photos (6)

2 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT

3 ft. - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

150.3 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SL

150.3 ft. - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES, Start - SL

154.3 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES - SL

195.8 ft. - General Observation - 21" VCP