- Date
- 11/21/2017
- W/O
- PENDING
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00659
- PipeID
- P13623
- Time
- 9:28 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- G7562R
- Sewer Name
- 16 LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Maintenance Related
- Project
- 20171121SHO_LAMANDA_PARK_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 22 in.
- Upstream MH
- 16 0572
- Downstream MH
- 16 0571
- Dir. of Survey
- Downstream
- Length Surveyed
- 252 ft.
- Total Length
- 252 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 3222
- O&M Rating
- 11
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole 16 0572 to 16 0571 Observation photos (5)

9.5 ft. - Roots Tap Barrell, at 11 o'clock, 10 %, within 8 inches of joint: YES - BEFORE

9.5 ft. - General Photograph - ROOTS CUT (AFTER)

85.7 ft. - Roots Tap Barrell, at 11 o'clock, 5 %, within 8 inches of joint: NO - AFTER CUTTING

160.3 ft. - Roots Fine Barrell, at 11 o'clock, within 8 inches of joint: NO

249.1 ft. - Roots Fine Barrell, at 12 o'clock, within 8 inches of joint: NO