Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2017, 12:50 PM
  • 05 1726_05 1725_11172017_045517.mp4

Date
11/17/2017
W/O
0674089
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00471
PipeID
P06953
Time
4:50 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
H0674
Sewer Name
05 LOMITA TRUNK
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Capital Improvement Program Assesment
Project
20171117MDM_LOMITA_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
05 1726
Downstream MH
05 1725
Dir. of Survey
Downstream
Length Surveyed
319.9 ft.
Total Length
319.9 ft.
Structural Index
3
Structural Quick
3827
Structural Rating
38
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
44
Pipe schematic from manhole 05 1726 to 05 1725
MH: 05 1726MH: 05 1725downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:55AM0 ft. MWM - Water Mark, 60 %of cross sectional area8 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - HAIRLINE13.5 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - H55.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active106.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open108.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H108.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H125.6 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H127.4 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Finish - H127.4 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - SLIGHT141.6 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT141.6 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Finish - H146.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H161.7 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: NO - SLIGHT195.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active230.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H236.9 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Finish - SLIGHT236.9 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Finish - SLIGHT236.9 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - H236.9 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - H256.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL258.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL289.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open298.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H316.9 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES319.6 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active319.6 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Finish - HAIRLINE319.6 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Finish - HAIRLINE319.9 ft. AMH - Downstream Manhole, Survey Ends - 5:40AM

Observation photos (7)

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    8 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - H

    13.5 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    127.4 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    141.6 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: NO - SLIGHT

    161.7 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: NO - SLIGHT

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - H

    236.9 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - H

    236.9 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES, Start - H

Observations (31)

DistanceCodeObservation
55.7TFActive
256.1FCSL
316.9DSGV
141.6FSSLIGHT
319.6MGOConn. @ Mh, 9 O' Clock. Active
319.6FSHAIRLINE
0MWL
108.7FCH
13.5FSH
195.2TFActive
236.9FSSLIGHT
0AMH4:55AM
289.7TFOpen
106.8TFOpen
161.7FSSLIGHT
236.9FSSLIGHT
236.9FSH
298.7FCH
319.9AMH5:40AM
230.6FCH
125.6FCH
319.6FSHAIRLINE
127.4FSH
108.7FLH
0MWM
127.4FSSLIGHT
141.6FSH
236.9FSH
8FSHAIRLINE
146.4FCH
258.7FCSL

Properties (6)

custom_field_three
SLIGHT SPRIAL FRACTURE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2017-11-17T04:50:53-08:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false